• Fritsch GmbH Mahlen und Messen | Probenaufbereitung und Partikelmessung

    • Products
    • Solutions
    • Service
    • News
    • About us
    • Contact
    • Home
    • Contact
    • Print
    • erp
    • English USA
    • English UK
    • Deutsch
    • French
    • Russian
    • IT
    • ES
    • Chinese
    • Japanese
    • Home
    • ·
    • Solutions
    • ·
    • Industries
    • ·
    • Pharmaceuticals
    • ·
    • Reports from this industry
    • ·
    • Analysis of active components of certain medications
      • Industries
        • Construction materials
        • Biology
        • Chemistry
        • Mechanochemistry
        • Agriculture and forestry
        • Geology / mineralogy
        • Ceramics / glass industry
        • Plastics / textiles
        • Foodstuffs
        • Metallurgy
        • Environment
        • Pharmaceuticals
          • Reports from this industry
          • Grinding reports from this industry
      • Product Finder
      • Grinding reports

      Contact Applications Laboratory

      FRITSCH Applications Laboratory Ulrich Gerber
      Ulrich Gerber

      Phone: 0049 67 84 70 122

      gerber(at)fritsch.de

    • FRITSCH mills in the pharmaceutical industry

      Your application - our solution: Find out more about the perfect sample preparation in the pharmaceutical industry. Read our application reports with tips about comminution or take a look in our practical grinding report data base with numerous sample grindings with detailed information.  

       

      • Reports from this industry
      • Grinding reports from this industry

      Analysis of active components of certain forms of medication

      In these the desired active pharmaceutical ingredients are added. In order to varify in regards to quality management that the desired amount of pharmaceutical ingredients was added in a tablet, an element analysis is performed. Hereby the tablet is pulverized. With the FRITSCH Mortar Mill PULVERISETTE 2, 10 - 20 tablets are ground. In order for no ingredients to disappear due to the application of energy, the mortar mill is the proper choice. The grinding action of the pestle does not increase the temperature during the grinding process. The pharmaceutical ingredients remain constant. After a grinding duration of 1 - 5 minutes a homogenous powder is achieved with a particle size of < 100 µm. We recommend grinding sets made of agate or hard porcelain. Even dragées or coated tablets may be ground. But here sometimes the coating is not ground perfectly.

      Downloads / Grinding reports / Links

      Download the FRITSCH-report as PDF-file

      Analysis of active components of various forms of medication

       

      Detailed grinding reports

      Tablets

       

      Additional literature

      Galenics

      Tablets

      back

    • Direct links
    • Login
    • Contact
    • Purchase & Payment Terms
    • Imprint
    • Recommend page
    • Print
    • Sample Preparation
    • Particle Sizing
      • Contact / Service / News

         

        Contact

        Application Consultation

        Technical Support

        Contact worldwide

         

        Service

        Application Consultation

        Technical Support

        Your Application - Our Solution

        Product Finder

        Grinding reports database

        Free-of-charge sample preparation

        Contact worldwide

        Downloads

        Online guarantee

        QA certificates

         

        News

        News

        Roadshows

        Workshops

        Fairs

         

      • Products for Sample Preparation

         

        Milling

        Planetary Mills

        Ball Mills

        Cutting Mills

        Rotor / Beater Mills

        Jaw Crushers / Disk Mills

        Mortar Grinder

         

        Sieving

        Vibratory Sieve Shakers

        Heavy Duty Analytical Sieve Shaker

         

        Dividing / Feeding / Cleaning

        Sample Dividers

        Vibratory Feeders

        Ultrasonic Cleaners

      • Products for Particle Sizing

         

        Laser diffraction

        Measuring range 0.08 – 2000 µm

        Measuring unit

        Wet dispersion

        Dry dispersion

        Falling chute

        Small volume wet dispersion

        Software

         

        Measuring range 0.01 – 2000 µm

        Measuring unit

        Wet dispersion

        Dry dispersion

        Falling chute

        Small volume wet dispersion

        Software

         

        Dynamic light scattering DLS:

        Measuring range 1 nm – 6 µm

      • Links

         

        Further domains

        www.fritsch.de

        www.fritsch-france.fr

        www.fritsch.com.ru

        www.fritsch.es

        www.fritsch-italy.it

        www.fritsch.com.sg

        www.fritsch.cn

        www.fritsch.jp

        www.fritsch.kr

         

        www.fritsch-sizing.com

        www.fritsch-sizing.de

        www.fritsch-sizing.fr

        www.fritsch-sizing.ru

        www.fritsch-sizing.es

        www.fritsch-sizing.it

        www.fritsch-sizing.com.sg

        www.fritsch-sizing.cn

        www.fritsch-sizing.jp

        www.fritsch-sizing.co.kr

      • For registered users

        Enter your email address and password:

        Forgot your password?

      • Please complete the form below for your account: